        Cleaning of ceramic membrane equipment. Time:2018.01.30
        The following is the specific cleaning process of ceramic membrane device:
        Pure water cleaning
        Flush the equipment to the system with pure water.
        Alkaline cleaning
        Using pure water as 1% to 3%, the temperature of 60-70 ℃ of NaOH aqueous solution, cleaning about 50 minutes. Rinse with pure water to neutral.
        Acid cleaning
        Using pure water as 1%, citric acid aqueous solution for 30 to 40 ℃, temperature cleaning about 50 minutes. Rinse with pure water to neutral.
        Note:
        For the first time, the film should be recycled. The method is:
        Alkaline cleaning:
        With temperature is about 60-70 ℃, the concentration of 1% NaOH solution cleaning, time for about 30 minutes with deionized water rinse to neutral;
        Pickling:
        With temperature is about 30 to 40 ℃, the concentration of 1% lemon acid solution to clean, time for about 30 minutes with deionized water rinse to neutral.